Tel: +36-20-344-1787, E-mail: rapaskft@rapas.hu

2500 and 5000V insulation testers, FR3025 / FR3025E

2500 V test voltage (5000 V for FR3025E), 200 GΩ mesuring range. DAR /PI and AC/DC voltage masurements 

FR3025  / FR3025E  insulation testers features

  • Rated measuring voltage:
    • 100V~2.5kV (FR3025)
    • 250V~5kV (FR3025E)
  • Insulation resistance range: 0.01 MΩ ~ 200 GΩ
  • DAR, PI measurement
  • DC voltage measurement range: 0 ~ 1000 V
  • AC voltage measurement range: 0 ~ 750 V
  • Object automatic discharge3
  • Automatic range selection
  • Data storage: 500 measurement groups
  • Automatic turn off

FR3025 digital insulation tester can perform insulation tests up to 2.5 kV, and the FR2025E version up to 5 kV. The large measuring range with automatic range selection extends to 200 GΩ for both versions. In addition to the insulation test, the instruments are also capable of measuring absorption ratio, polarization index, DC voltage up to 1000 V and AC voltage of 750 V.

The stable measuring voltage, high accuracy and interference suppression, easy handling and the light weight ensures fast and reliable testing.

The shock-, dust- and moisture-resistant housing makes the instrument safe to use even in harsh environmental conditions

Specifications

RAnge Best Resolution Accuracy
FR3025
Rated test voltage: 100V, 250V, 500V, 1000V, 2500V ±10%
0,01 MΩ~200 GΩ 0,01MΩ ±3% MÉ ±5 digits
FR3025E
Rated test voltage: 250V, 500V, 1000V, 2500V, 5000V ±10%
0,01 MΩ~200 GΩ 0,01MΩ ±3% MÉ ±5 digits
  • Reference conditions: 23±5°C,≤75% relative humidity
  • Automatic range selection
  • Short-circuit current: ≥2mA
  • Capacitive load: max. 1 µF
  • Measuring DAR and PI
  • DC voltage: 0~1000V, resolution: 0.1V
  • AC voltage: 0~750V, resolution: 0.1V
  • Power supply: DC 9V 6xLR14 alkaline battery
  • Low battery status indication: empty battery symbol
  • Display: 4-digit, large, backlit LCD, 108×65 mm
  • Dimensions: H/W/H: 240 × 188 × 85 mm
  • Weight: 1230 g (with battery)
  • Alarm if the measured value is greater than the set value
  • Measurement time: voltage 2/sec, insulation resistance 7 sec/measurement
  • Internal memory: 500 data groups, data can be recalled to the display
  • Automatic turn off: after 15 minutes
  • Operating temperature and humidity: -10... +40°C, <80% RH
  • Storage temperature and humidity: -20... +60°C, <70% RH
  • Relevant standards / regulations: IEC61326 (EMC), IEC61010-1 (CAT III 300V, CAT IV 150V, pollution degree: 2

Accessories

  • High-voltage measuring tip with red cable 1 m, high-voltage measuring wire black 1 m, green 1 m
  • Carry bag
  • Measuring tweezers
  • Measurement report
  • User Manual